iTHERM TM411
Innovative advanced, modular RTD thermometer

iTHERM TM411
Innovative advanced, modular RTD thermometer ©Endress+Hauser
iTHERM TM411
Innovative advanced, modular RTD thermometer ©Endress+Hauser

For use in hygienic and aseptic applications in the Food & Beverages and Life Sciences industries

It has been designed to meet the requirements of the Food & Beverages and Life Sciences industries and complies with the highest quality standards. It offers a variety of versions within a clearly segmented standard product. The result: Time and cost savings by simple and fast product selection. It offers many technical innovations: iTHERM QuickSens, StrongSens or QuickNeck. This leads to distinctive reduction of maintenance costs, improved product quality, process efficiency and safety.

  • 장점

    • User-friendly and reliable from product selection to maintenance

    • iTHERM inserts: globally unique, fully-automated production. Full traceability and consistently high product quality for reliable measured values

    • iTHERM QuickSens: fastest response times (...

  • 적용 분야

    • Specially designed for use in hygienic and aseptic applications in the Food & Beverages and Life Sciences industries

    • Measuring range: –200 to +600 °C (–28 to +1 112 °F)

    • Pressure range up to 40 bar (580 psi)

    • Protection class: up to IP69K

특징 및 사양

뒤로

Details

  • 측정 원리

    Resistance Temperature Detector

  • Characteristic / Application

    metric style

    modular temperature assembly

    hygienic/aseptic design (3-A®, EHEDG, ASME BPE, FDA)

    hygienic process connections

    with neck

    suitable for hazardous areas

    incl. protection tube

    QuickSens for fastest response time

    StrongSens for most robust design

    QuickNeck for easy and cost saving recalibration

  • Terminal head

    TA30A - E+H, aluminium - cover low, hinged - w. or w/o. display

    TA30D - E+H, aluminium - cover high, hinged

    TA30R - stainless steel blasted - screwed cover - w. or w/o. display

    TA30R - stainless steel handpolished - screwed cover - w. or w/o.
    display

    TA30S - polypropylene - screwed cover

    TA30P - polyamide - cover high, hinged

  • Thermowell / protection tube

    without

    incl. thermowell

    incl. T-/ellbow thermowell

  • Insert / probe

    mineral insulated (MI), flexible

    pipe version, isolated wires, not flexible

  • Outer diameter protection tube / Insert

    6,0 mm (0,24")

    9,0 mm (0,35")

    12,7 mm (0,5")

  • Material protection tube/ thermowell

    1.4435 delta-ferrit < 1%

    316L

  • Process connection

    compression fitting

    weld in adapter

    clamp connections acc. to ISO2852

    screwed pipe joint acc. to DIN 11851

    aseptic screwed pipe joint acc. to DIN 11864-1

    metallic sealing system

    thread acc. to ISO 228 for liquiphant adaptor

    APV Inline

    Varivent

    Ingold

    SMS 1147

    Neumo Biocontrol

    T- and corner pieces

  • Tip shape

    straight

    reduced

    tapered

  • Surface roughness Ra

    0,76 μm (29,92 μin)

    0,38 μm (14,96 μin)

    0,38 μm (14,96 μin) electropolished

  • Operating temperature range

    PT100:

    -200 °C … 600 °C

    (-328 °F … 1.112 °F)

    StrongSens:

    -50 °C … 500 °C

    (-58 °F … 932 °F)

    QuickSens:

    -50 °C … 200 °C

    (-58 °F … 392 °F)

  • Max. process pressure (static)

    at 20 °C: 40 bar (580 psi)

  • Accuracy

    class A acc. to IEC 60751

    class AA acc. to IEC 60751

  • Response time

    depending on configuration

    QuickSens: t90 = 1,5 s

    StrongSens: t90 = 9,5 s

  • Integration head transmitter

    yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

  • Ex - approvals

    ATEX II

    ATEX IECEx

    FM

    CSA

    NEPSI

    CRN

  • Certification

    SIL (transmitter only)

문서 / 매뉴얼 / 소프트웨어

액세서리 / 예비 부품

Nr
Order code
Specification