Vibronic
Point level detection
Nivotester FTL325P

Nivotester FTL325P ©Endress+Hauser
Nivotester FTL325P ©Endress+Hauser

Switching unit with intrinsically safe signal circuit for connection to Liquiphant or Soliphant

The switching unit FTL325P is used for point level detection in liquid tanks and bulk material silos, also in hazardous explosion areas. Also suitable for liquid detection in pipes for dry running protection for pumps and overfill prevention for tanks with combustible or non-combustible liquids harmful to water. Up to 3 measuring devices for two-point control and point level detection. Functional safety up to SIL3 in accordance to IEC 61508 using Liquiphant with electronic insert FEL57.

빠른 선택

제안된 옵션 중에서 선택하십시오.
  • <%label%>
    • 더 많은 옵션을 찾고 계십니까? 계속하려면개별 사양 구성을 사용하십시오.
  • <%feature%>
      <%label%>
    • 더 많은 옵션을 찾고 계십니까? 계속하려면개별 사양 구성을 사용하십시오.
  • Process Connection
  • <%message%>

또는

개별 사양 구성

가능한 모든 옵션에서 선택을 계속하십시오.
  • 장점

    • Nivotester FTL325P for connecting one, two or three measuring cells (1-, 2- or 3-channel devices)

    • Intrinsically safe signal circuits Ex ia for use of measuring sensor in explosion hazardous areas

    • Functional safety up to SIL2 through line monitoring....

  • 적용 분야

    Switching unit with intrinsically safe signal circuit for connection to Liquiphant or Soliphant.

    • Ambient temperature: -20 to +70°C (-4 to +158°F)

    • International explosion protection certificates, overfill prevention WHG, marine approvals

Details

  • 측정 원리

    Vibration Liquids

  • Characteristic / Application

    Switching unit PFM technology for rail mounting
    Intrinsically safe
    Highest SIL safety

  • Specialities

    If sensors are redundant, SIL3

  • Supply / Communication

    85...253 V AC,

    20...30 V AC/ 20...60 V DC

  • Ambient temperature

    Single installation:
    -20 °C ... 60 °C
    (-4 °F ... 140 °F)
    Rail mounting:
    -20 °C ... 50 °C
    (-4 °F ... 122 °F)

  • Communication

    1 Channel: 1 Level SPDT + 1 Alarm SPST
    3 Channel: 3 level SPDT + 1 Alarm SPST

  • Certificates / Approvals

    ATEX, FM, CSA, IEC Ex, TIIS, INMETRO, NEPSI, EAC

  • Safety approvals

    Overfill prevention WHG

    SIL

  • 측정 원리

    Vibration Solids

  • Characteristic / Application

    Switching unit PFM technology for rail mounting
    Intrinsically safe

  • Supply / Communication

    85...253 V AC,

    20...30 V AC / 20...60 V DC

  • Ambient temperature

    Single installation:
    -20 °C ... 60 °C
    (-4°F ... 140 °F)
    Rail mounting:
    -20 °C ... 50 °C
    (-4 °F ... 122 °F)

  • Communication

    1 Channel: 1 Level SPDT + 1 Alarm SPST
    3 Channel: 3 level SPDT + 1 Alarm SPST

  • Certificates / Approvals

    ATEX, FM, CSA, IEC Ex, TIIS, INMETRO, NEPSI

  • Safety approvals

    Overfill prevention WHG

    SIL

문서 / 매뉴얼 / 소프트웨어

액세서리 / 예비 부품

Nr
Order code
Specification