Guided radar measurement
Time-of-Flight
Levelflex FMP53

Levelflex FMP53 ©Endress+Hauser

Time-of-Flight measuring principle

Commissioning movie for Levelflex FMP5x guided radar and Micropilot FMR5x free space radar

Unique HistoROM data management concept for safe level measurement

Continuous adapting algorithms offering safe level measurement due to Multi-Echo Tracking

Multi-Echo Tracking with Tank Trace marks and traces all echoes signals, not only the level signal - guaranteeing safe measurement at any time

Levelflex FMP53 ©Endress+Hauser

For the highest hygiene requirements in the food and life sciences industry

Levelflex FMP53 for continuous level measurement for hygienically sensitive applications in the food and life sciences industry. FMP53 meets the hygiene requirements according to ASME BPE and USP Class VI. The unique in situ validation without dismantling from the process is a cost saving advantage. FMP53 guided radar offers maximum reliability even in case of moved surface and foam, for changing medias and in case of filling via spray head.

  • 장점

    • Reliable measurement even for changing product and process conditions

    • HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics

    • Highest reliability due to new Multi-Echo Tracking evaluation

    • Hardware and software...

  • 적용 분야

    Version with rod probe.

    • Process connections: For hygiene requirements (Tri-Clamp, 11851, 11864, NEUMO,
      Varivent N, SMS)

    • Temperature: -20 to +150°C (-4 to +302°F)

    • Pressure: -1 to +16bar (-14.5 to +232psi)

    • Maximum measuring range: Rod 6m (20ft)

    • ...

특징 및 사양

뒤로

Details

  • 측정 원리

    Guided radar

  • Characteristic / Application

    Premium device. Hygiene

    Rod probe,
    ASME BPE + USP Class VI compliant, Integrated data memory, Factory precalibrated, Reliable measuring: in case of moved surface + foam, for changing medias, for filling via spray head.

  • Specialities

    Heartbeat Technology,

    Bluetooth® commissioning,

    Operation and maintenance SmartBlue App,

    HistoROM,

    RFID TAG for easy identification

  • Supply / Communication

    2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus)

    4-wire (HART)

    Bluetooth® wireless technology and App (optional)

  • Accuracy

    Rod probe:+/- 2 mm (0.08 in)

  • Ambient temperature

    -40...+80 °C

    (-40...+176 °F)

  • Process temperature

    –20...+150 °C

    ( –4...+302 °F)

  • Process pressure absolute / max. overpressure limit

    Vacuum...16 bar

    (Vacuum...232 psi)

  • Main wetted parts

    Rod probe:

    304, 304L, 316L, PEEK

  • Process connection

    Thread:

    M24

  • Process connection hygienic

    Tri-Clamp

    DIN11851

    DIN11864-1

    NEUMO

    Varivent N

    SMS

  • Sensor length

    Rod probe: 6 m (20 ft)

  • Max. measurement distance

    Rod: 6 m (20 ft)
    Min DK>1.6

  • Communication

    4...20 mA HART

    PROFIBUS PA

    FOUNDATION Fieldbus

    Bluetooth® wireless technology

  • Certificates / Approvals

    ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, KC, EAC

  • Safety approvals

    Overfill prevention WHG

    SIL

  • Design approvals

    EN 10204-3.1

  • Hygienic approvals

    3A, EHEDG

    CoC ASME-BPE

  • Options

    Sensor remote with 3 m/9 ft or 6 m/18 ft cable,

    Weld-in adpater,

    Remote operation via SmartBlue App using Bluetooth®

  • Application limits

문서 / 매뉴얼 / 소프트웨어