사양 정보
-
Sampling probe compatibility
Raman Rxn-10 probe
-
Wetted materials
Body: 316L stainless steel
Window: Proprietary material, optimized for bioprocesses
Process connection: PG13.5
Surface finish: Ra 15 with electropolish
Adhesive: USP Class VI and ISO 10993 compatible -
Sterilization method
Autoclave
적용 분야
Raman bIO-Optics are versatile immersion optics used in conjunction with the Rxn-10 probehead and compatible with standard bioreactor ports. The fixed focus design provides long-term measurement stability along with superior signal performance, essential for transferable, high performance Raman-based bioprocess analysis. Available in industry standard lengths, Raman bIO-Optics are ideally suited for both glass and plastic benchtop bioreactor/fermenter applications requiring headplate entry.
Cell culture: glucose, lactate, glutamine, amino acids, cell density, titer
Fermentation: glycerol, methanol, ethanol, sorbitol, biomass
Downstream: aggregation, protein crystallization, formula stability, product CQA, protein concentration, buffer excipients
장점
Immersion optics for multi-component bioprocess measurement
Compatible with standard bioreactor ports
Fixed-focus design
Available in 12 mm diameter with Pg 13.5 threaded connector
120, 220, 320, or 420 mm lengths
Autoclavable
FLEX 선택 | 기술적 우수성 | 단순성 |
---|---|---|
Fundamental 선택 기본적인 측정 요구사항 충족 |
기술적 우수성
|
단순성
|
Lean 선택 핵심 프로세스를 손쉽게 처리 |
기술적 우수성
|
단순성
|
Extended 선택 혁신적인 기술로 프로세스 최적화 |
기술적 우수성
|
단순성
|
Xpert 선택 가장 까다로운 어플리케이션 요구사항 충족 |
기술적 우수성
|
단순성
구성에 따라 다름 |
-
-
기술 정보(TI)
Accessory Optics for the Rxn-10 Probe Technical Information
System design and specifications for Rxn-10 probe optics:
Raman immersion optics (KIO1),
non-contact optics (KNCO1), bIO-Optics (KLBIO1),
bio multi optics (KRBMO), bio sleeves (KRBSL),
and Raman optic system for single use (KRSU1)EN KO 31/05/202303/08/2022언어:
영어
버전:
31/05/2023
파일 크기:
467.9 KB
파일 이름:
TI01635CEN_0322.pdf
-
-
-
기술 정보(TI)
Rxn-10 Raman Spectroscopic Probe Technical Information
System design and specifications
for the Raman Rxn-10 probe언어:
영어
버전:
31/05/2023
파일 크기:
423 KB
파일 이름:
TI01629CEN_0322.pdf
-
-
-
사용 설명서(BA)
Accessory optics for the Rxn-10 Probe Operating Instructions
Commissioning, operation, and maintenance details
for Rxn-10 probe optics: Raman immersion optics (KIO1),
non-contact optics (KNCO1), bIO-Optics (KLBIO1),
bio multi optics (KRBMO), bio sleeves (KRBSL)
and Raman optic system for single use (KRSU1)EN KO 31/05/202303/08/2022언어:
영어
버전:
31/05/2023
파일 크기:
1.8 MB
파일 이름:
BA02171CEN_0322.pdf
-
-
-
사용 설명서(BA)
Rxn-10 Raman Spectroscopic Probe Operating Instructions
Commissioning, operation, and maintenance details
for the Raman Rxn-10 probe언어:
영어
버전:
31/05/2023
파일 크기:
1.2 MB
파일 이름:
BA02160CEN_0322.pdf
-
-
-
요약 지침서(KA)
Rxn-10 Raman Spectroscopic Probe Brief Operating Instructions
Quick start guide for the Raman Rxn-10 probe
언어:
영어
버전:
31/05/2023
파일 크기:
895.3 KB
파일 이름:
KA01546CEN_0322.pdf
-
-
-
요약 지침서(KA)
Accessory Optics for the Rxn-10 Probe Brief Operating Instructions
Quickstart guide for Rxn-10 probe optics:
Raman immersion optics (KIO1),
non-contact optics (KNCO1), bIO-Optics (KLBIO1),
bio multi optics (KRBMO), bio sleeves (KRBSL)
and Raman optic system for single use (KRSU1)EN KO 31/05/202303/08/2022언어:
영어
버전:
31/05/2023
파일 크기:
1 MB
파일 이름:
KA01551CEN_0322.pdf
-
-
-
PU (출판물)
Raman application guide for the life science industry - Trusted composition analysis for the life sciences
A guide to our Raman spectroscopy application notes for the
Life Science industry (featuring the Raman Rxn2 analyzer,
Raman Rxn4 analyzer, Rxn-10 probe, Rxn-20 probe, Rxn-45 probe,
Rxn-46 probe, and probe accessory optics (bIO-Optic, Raman single
use optic system / SUB, immersion optic, non-contact optic).언어:
영어
버전:
19/04/2022
파일 크기:
1.1 MB
파일 이름:
PU01447CEN_0222.pdf
-
-
-
혁신(IN)
Raman technology in bioprocessing - Scalable in situ bioprocess monitoring enabling advanced process control
An overview brochure about our Raman spectroscopy analyzer
and probe portfolio, powered by Kaiser Raman technology, for
the bioprocessing / biopharmaceutical industry (including the
Raman Rxn2 analyzer, Raman Rxn4 analyzer, Rxn-10 probe,
Rxn-45 probe, Rxn-46 probe, and probe accessory optics (bIO-Optic,
Raman single use optic system, bio multi optic with bio sleeve, and
Raman flow assembly), powered by Kaiser Raman technology.언어:
영어
버전:
19/06/2023
파일 크기:
6.8 MB
파일 이름:
IN01228CEN_0223.pdf
-
-
-
혁신(IN)
Raman spectrographic probes - Robust optical measurement of chemical composition
An overview brochure about our Raman spectroscopy probe
portfolio including the Rxn-10 probe, Rxn-20 probe, Rxn-30 probe,
Rxn-40 probe, Rxn-41 probe, Rxn-45 probe, Rxn-46 probe, and
probe accessory optics (bIO-Optic, Raman single use optic system /
SUB, immersion optic , non-contact optic), powered by Kaiser Raman
technology.언어:
영어
버전:
26/10/2021
파일 크기:
4.9 MB
파일 이름:
IN01225CEN_0121.pdf
-
-
-
혁신(IN)
Technologie Raman pour les bioprocédés
Surveillance évolutive des bioprocédés in situ et contrôle
avancé des process언어:
French
버전:
08/02/2024
파일 크기:
1.3 MB
파일 이름:
IN01228CFR-Raman bioprocedes.pdf
-