Soliphant II FTM31S

Product picture of: Soliphant II FTM31S

이 제품은 더 이상 제공되지 않습니다.

구모델 / 신모델 섹션에서 신모델을 확인하거나 Endress+Hauser로 문의하시기 바랍니다.

특징 및 사양

뒤로

Details

  • 측정 원리

    Vibration Solids

  • Characteristic / Application

    Level limit switch for powder and bulk solids
    Fork sensor
    Universal
    No calibration required
    Not affected by build up
    Robust
    Switch value visible from outside
    Explosion protection EEx ia
    Tube extension

  • Supply / Communication

    Transmitter
    2-wire Pulse Frequency Modulation

  • Ambient temperature

    -40°C...70°C

  • Process temperature

    -40°C...150°C

  • Process pressure absolute / max. overpressure limit

    Vacuum...16bar

  • Min. density of medium

    20g/l (8g/l on request)

  • Main wetted parts

    304 / 316Ti

  • Process connection

    Thread
    1 1/2" DIN2999
    1 1/2" NPT
    EN Flange DN 50...100
    ASME Flange 2"...4"
    Jis Flange 50A...100A

  • Sensor length

    400mm...4000mm

  • Communication

    2-wire Pulse Frequency Modulation
    Interface module:
    Level and Alarm relay
    FTL325P/FTL375P:
    Level and Alarm relay

  • Certificates / Approvals

    ATEX
    FM
    CSA

  • Components

    Transmitter:
    FTL325P, FTL375P

  • Successor

    FTM51

  • Application limits

    Grain size: max 10 mm

문서 / 매뉴얼 / 소프트웨어

액세서리 / 예비 부품

Nr
Order code
Specification
  • 기존 제품

  • 신제품