사양 정보
-
Sampling probe compatibility
Raman Rxn-10 probe
적용 분야
Developed according to industry standards for single-use sensors, this Raman optic system is cGMP qualified and gamma sterilizable. The system is comprised of two parts - a reusable optic and a disposable fitting for single-use bioreactors (SUB). The Raman optic system for single use in conjunction with the Rxn-10 probe offers the same quality data as reusable Raman probes. This ability allows customers to develop products and processes without limitations of the final production reactor type.
Cell culture: glucose, lactate, amino acids, cell density, titer
Fermentation: glycerol, methanol, ethanol, sorbitol, biomass
장점
Disposable fitting for single-use bioreactors (SUB), plus a non-contact reusable optic
Developed to industry standards for single-use sensors
Gamma sterilizable
Tested and supplied by multiple SUB vendors
FLEX 선택 | 기술적 우수성 | 단순성 |
---|---|---|
Fundamental 선택 기본적인 측정 요구사항 충족 |
기술적 우수성
|
단순성
|
Lean 선택 핵심 프로세스를 손쉽게 처리 |
기술적 우수성
|
단순성
|
Extended 선택 혁신적인 기술로 프로세스 최적화 |
기술적 우수성
|
단순성
|
Xpert 선택 가장 까다로운 어플리케이션 요구사항 충족 |
기술적 우수성
|
단순성
구성에 따라 다름 |
-
-
기술 정보(TI)
Accessory Optics for the Rxn-10 Probe Technical Information
System design and specifications for Rxn-10 probe optics:
Raman immersion optics (KIO1),
non-contact optics (KNCO1), bIO-Optics (KLBIO1),
bio multi optics (KRBMO), bio sleeves (KRBSL),
and Raman optic system for single use (KRSU1)EN KO 31/05/202303/08/2022언어:
영어
버전:
31/05/2023
파일 크기:
467.9 KB
파일 이름:
TI01635CEN_0322.pdf
-
-
-
기술 정보(TI)
Rxn-10 Raman Spectroscopic Probe Technical Information
System design and specifications
for the Raman Rxn-10 probe언어:
영어
버전:
31/05/2023
파일 크기:
423 KB
파일 이름:
TI01629CEN_0322.pdf
-
-
-
사용 설명서(BA)
Accessory optics for the Rxn-10 Probe Operating Instructions
Commissioning, operation, and maintenance details
for Rxn-10 probe optics: Raman immersion optics (KIO1),
non-contact optics (KNCO1), bIO-Optics (KLBIO1),
bio multi optics (KRBMO), bio sleeves (KRBSL)
and Raman optic system for single use (KRSU1)EN KO 31/05/202303/08/2022언어:
영어
버전:
31/05/2023
파일 크기:
1.8 MB
파일 이름:
BA02171CEN_0322.pdf
-
-
-
사용 설명서(BA)
Rxn-10 Raman Spectroscopic Probe Operating Instructions
Commissioning, operation, and maintenance details
for the Raman Rxn-10 probe언어:
영어
버전:
31/05/2023
파일 크기:
1.2 MB
파일 이름:
BA02160CEN_0322.pdf
-
-
-
요약 지침서(KA)
Rxn-10 Raman Spectroscopic Probe Brief Operating Instructions
Quick start guide for the Raman Rxn-10 probe
언어:
영어
버전:
31/05/2023
파일 크기:
895.3 KB
파일 이름:
KA01546CEN_0322.pdf
-
-
-
요약 지침서(KA)
Accessory Optics for the Rxn-10 Probe Brief Operating Instructions
Quickstart guide for Rxn-10 probe optics:
Raman immersion optics (KIO1),
non-contact optics (KNCO1), bIO-Optics (KLBIO1),
bio multi optics (KRBMO), bio sleeves (KRBSL)
and Raman optic system for single use (KRSU1)EN KO 31/05/202303/08/2022언어:
영어
버전:
31/05/2023
파일 크기:
1 MB
파일 이름:
KA01551CEN_0322.pdf
-
-
-
PU (출판물)
Raman application guide for the life science industry - Trusted composition analysis for the life sciences
A guide to our Raman spectroscopy application notes for the
Life Science industry (featuring the Raman Rxn2 analyzer,
Raman Rxn4 analyzer, Rxn-10 probe, Rxn-20 probe, Rxn-45 probe,
Rxn-46 probe, and probe accessory optics (bIO-Optic, Raman single
use optic system / SUB, immersion optic, non-contact optic).언어:
영어
버전:
19/04/2022
파일 크기:
1.1 MB
파일 이름:
PU01447CEN_0222.pdf
-
-
-
PU (출판물)
Raman calibration and verification kits - Everything needed to calibrate and verify your Raman analyzer system for lab-to-process scalability
An overview of the Raman calibration and verification kits for
the bio multi optic / single use optic and the Raman flow assembly
(includes the flow bench and flow cell). These kits are to be used in
conjunction with the Rxn-10 probe and Raman Rxn2 / Rxn4 analyzer
for upstream and downstream bioprocessing (powered by Kaiser
Raman technology).언어:
영어
버전:
13/12/2023
파일 크기:
2.1 MB
파일 이름:
PU01518CEN_0223.pdf
-
-
-
PU (출판물)
Lab-to-process monitoring & control in Life Sciences - Reliable measurement of bioprocess physical and chemical properties
A combined product list of analysis offerings from both Optical Analysis
and LIquid Analysis for bioprocessing applications in the life science
industry (including Raman Rxn2 analyzer, Raman Rxn4 analyzer,
Rxn-10 probe, bio multi optic and bio sleeve, Raman flow assembly,
Rxn-45 probe, Rxn-46 probe, Raman optic system for single use,
Memosens CPS61E, Memosens COS81E, OUSBT66, Memosens CPS61E,
Memosens CPS77E, Memosens CLS82E, OUSAF44, Memosens CPS11E,
Memosens CLS16E, TOC Analyzer CA79, Liquiline transmitter platform, and
Memobase software).언어:
영어
버전:
11/04/2024
파일 크기:
776.1 KB
파일 이름:
PU01484CEN_0224.pdf
-
-
-
혁신(IN)
Raman technology in bioprocessing - Scalable in situ bioprocess monitoring enabling advanced process control
An overview brochure about our Raman spectroscopy analyzer
and probe portfolio, powered by Kaiser Raman technology, for
the bioprocessing / biopharmaceutical industry (including the
Raman Rxn2 analyzer, Raman Rxn4 analyzer, Rxn-10 probe,
Rxn-45 probe, Rxn-46 probe, and probe accessory optics (bIO-Optic,
Raman single use optic system, bio multi optic with bio sleeve, and
Raman flow assembly), powered by Kaiser Raman technology.언어:
영어
버전:
19/06/2023
파일 크기:
6.8 MB
파일 이름:
IN01228CEN_0223.pdf
-