0.25 to 600 mg TOC/l 1 to 2400 mg TOC/l 2.5 to 6000 mg TOC/l 5 to 12000 mg TOC/l With the optional pre-dilution the measuring range will expand by the factor of 20
CA72TOC는 다양한 산업 분야에서 총 유기 탄소(TOC) 함량을 측정합니다. 염분, 지방 또는 섬유의 부하가 높은 혹독한 어플리케이션에서도 정확하고 신뢰할 수 있는 측정을 보장합니다. 또한 생산물 손실을 정확하게 검출해 프로세스 수율이 증가하고 비용을 절약할 수 있습니다. CA72TOC는 뛰어난 장기 안정성과 가용성으로 플랜트의 운영 안전성을 극대화하며, 명확한 진단 메시지로 예측 유지보수 전략을 지원합니다.
The monitoring solution provides the Visp fish farm with stable, reliable oxygen control, enabling optimal conditions for fish and reducing effort and risk.
Proline Teqwave MW 300 delivers stable real-time data taken directly from the process, reduces maintenance work, and allows quicker intervention if changes to the process are required.
Kerry DCF produces spreads and butter products for the retail market. The company wanted to automate its test for chemical oxygen demand in its treated effluent to save time and optimise the process.
Memosens CPS11E ensures precise pH monitoring in biodiesel production, improving product quality, process stability and sensor lifetime under harsh conditions.
Bonumose decided to enhance, automate and digitalize its tagatose sweetener manufacturing process with Endress+Hauser instrumentation to reach its company growth goals
Analyzer for online-determination of TOC in aqueous media using thermic catalytic combustion
Size
1558 x 785 x 400 mm 61.3 x 30.9 x 15.8 inch
Design
IP54
Process temperature
0 to 40 °C (32 to 104 °F)
Ambient temperature
5 to 35 °C (41 to 95 °F)
Process pressure
Pressure free
Sample flow rate
20 ml/min (0.32 US gal/hr)
Consistency of the sample
Aqueous Flammable substances are not allowed in ignitable concentrations, in such cases a sample dilution is required
Specials
Heatable Salt Trap Exchange furnace concept pH-controlled acid dosage with TIC stripping
Application
Industrial wastewater monitoring Control of process wastewater Monitoring of industrial surface water Recording of the carbon load to control the nutrient dosage
Power supply
115 VAC, 230 VAC, 50/60Hz
Output / communication
0/4 to 20 mA, galvanically separated Two channel version has an addtional one RS 232 C, propietary, for data output and remote control (optional)
Input
8 signal inputs 24 V DC, ative, load max. 500 Ohm
Measuring range
0.25 to 600 mg TOC/l 1 to 2400 mg TOC/l 2.5 to 6000 mg TOC/l 5 to 12000 mg TOC/l With the optional pre-dilution the measuring range will expand by the factor of 20
Active barrier, 1 channel for 4 to 20 mA, HART® transparent with 24 to 230 V AC/DC as well as active/passive input and output, optionally with SIL and Ex
Active barrier, 1 channel for 4 to 20 mA, HART® transparent with 24 to 230 V AC/DC as well as active/passive input and output, optionally with SIL and Ex