Levelflex M FMP45

Product picture of: Levelflex M FMP45

이 제품은 더 이상 제공되지 않습니다.

구모델 / 신모델 섹션에서 신모델을 확인하거나 Endress+Hauser로 문의하시기 바랍니다.

특징 및 사양

뒤로

Details

  • 측정 원리

    Guided radar

  • Characteristic / Application

    Coaxial probe:
    not affected by nozzle dimensions or tank installations

    Rod probe:
    for measurement in highly viscous media

    Rope probe:
    large measurement range even with small process connection

  • Interface measurement

    Clean interfaces liquid / liquid

    Simultaneous measurment of interface and overall level

  • Supply / Communication

    2-wire (HART / PROFIBUS PA / FOUNDATION Fieldbus )

  • Accuracy

    Coaxial probe: +/-3 mm (0.12")
    Rod probe: +/-3 mm (0.12")
    Rope probe: +/-3 mm (0.12"), >10m:0.03%

  • Ambient temperature

    -40 °C ... 80 °C
    (-40 °F ... 176 °F)

  • Process temperature

    XT-Version:
    -200 °C ... 280 °C
    (-328 °F ... 536 °F)
    HT-Version:
    -200 °C ... 400 °C
    (-328 °F ... 752 °F)

  • Process pressure absolute / max. overpressure limit

    Vacuum ... 400 bar
    (Vaccum ... 5802 psi)

  • Main wetted parts

    Coaxial probe: 316L, Alloy C22
    Rod probe: 316L, Alloy C22
    Rope probe: 316

  • Process connection

    Flange:
    EN 1092-1 B: DN50, DN80, DN100
    ASME: 2", 3", 4"
    JIS: DN50, DN80, DN100

  • Sensor length

    Rod: 4 m (178")
    Coax: 4 m (178")
    Rope: 35 m (1378")

  • Application

  • Max. measurement distance

    Coaxial probe :
    4 m (178") Min. DK > 1.4
    Rod probe :
    4 m (178") Min. DK > 1.6
    Rope probe :
    35 m (1378") Min. DK > 1.6

  • Communication

    4 ... 20 mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Certificates / Approvals

    ATEX
    FM
    CSA
    WHG/ Overfill prevention
    SIL
    NACE
    EN10204-3.1

  • Successor

    FMP54

  • Application limits

    Horizontal storage tank cyl.:

    Use coax probe


    Interface measurement:

    Use coax system in favor (coax probe, bypass, stilling well)

문서 / 매뉴얼 / 소프트웨어

  • 기존 제품

  • 신제품