Deltatop DO61W

이 제품은 더 이상 제공되지 않습니다.

구모델 / 신모델 섹션에서 신모델을 확인하거나 Endress+Hauser로 문의하시기 바랍니다.

특징 및 사양

뒤로

Details

  • 측정 원리

    Differential pressure

  • Product headline

    Calculated volume or mass flow measurement. dp primary element (orifice).
    Orifice flange union with flange taps.

  • Sensor features

    Internationally standardized ISO5167-2.

    Including orifice flanges.

    Exchangeable orifice plate.

    Compact or remote design.

    Optimizable for minimized pressure loss, improved uncertainty or maximized Turndown.

    Deltabar S/M differential pressure transmitter.

  • Nominal diameter range

    DN 25...500

    1" ... 24"

  • Max. measurement error

    typically < 1% of calculated volume or mass acc. ISO5167 without calibration."

    Uncertainty of primary element excluding uncertainty of density or compensation."

  • Measuring range

    2.5 ... 50'000m3/h

  • Max. process pressure

    PN10 ... 160

    Cl.300 ... 2500

  • Medium temperature range

    Compact version:

    -200°C ... 200°C

    -328°F ... 392°F



    Remote version:

    -200°C ... 1000°C

    -328°F ... 1832°F

  • Degree of protection

    Transmitter (Deltabar):

    IP67

    NEMA6P

  • Display/Operation

    Transmitter (Deltabar):

    4-line display

    3 push buttons

    Quick setup

    HistoROM

  • Outputs

    Transmitter (Deltabar):

    4 ... 20 mA

  • Digital communication

    Transmitter (Deltabar):

    HART

    PROFIBUS PA

    FOUNDATION Fieldbus

  • Hazardous area approvals

    Transmitter (Deltabar):

    ATEX

    FM

    CSA

    IEC

    TIIS

    NEPSI

  • 측정 원리

    Differential pressure

  • Product headline

    Calculated volume or mass flow measurement. dp primary element (orifice).
    Orifice flange union with flange taps.

  • Sensor features

    Internationally standardized ISO5167-2.

    Including orifice flanges.

    Exchangeable orifice plate.

    Compact or remote design.

    Optimizable for minimized pressure loss, improved uncertainty or maximized Turndown.

    Deltabar S/M differential pressure transmitter.

  • Nominal diameter range

    DN 25...500

    1" ... 24"

  • Max. measurement error

    typically < 1% of calculated volume or mass acc. ISO5167 without calibration.

  • Measuring range

    0.1 ... 5'500m3/h

  • Max. process pressure

    PN10 ... 160

    Cl.300 ... 2500

  • Medium temperature range

    Compact version:

    -200°C ... 200°C

    -328°F ... 392°F



    Remote version:

    -200°C ... 1000°C

    -328°F ... 1832°F

  • Degree of protection

    Transmitter (Deltabar):

    IP67

    NEMA6P

  • Display/Operation

    Transmitter (Deltabar):

    4-line display

    3 push buttons

    Quick setup

    HistoROM

  • Outputs

    Transmitter (Deltabar):

    4 ... 20 mA

  • Digital communication

    Transmitter (Deltabar):

    HART

    PROFIBUS PA

    FOUNDATION Fieldbus

  • Hazardous area approvals

    Transmitter (Deltabar):

    ATEX

    FM

    CSA

    IEC

    TIIS

    NEPSI

  • 측정 원리

    Differential pressure

  • Product headline

    Calculated volume or mass flow measurement. dp primary element (orifice).
    Orifice flange union with flange taps.

  • Sensor features

    Internationally standardized ISO5167-2.

    Including orifice flanges.

    Exchangeable orifice plate.

    Compact or remote design.

    Optimizable for minimized pressure loss, improved uncertainty or maximized Turndown.

    Deltabar S/M differential pressure transmitter.

  • Nominal diameter range

    DN 25...500

    1" ... 24"

  • Max. measurement error

    typically < 1% of calculated volume or mass acc. ISO5167 without calibration.

    Uncertainty of primary element excluding uncertainty of density or compensation.

  • Measuring range

    2.5 ... 50'000 m3/h

    12.5 ... 250'000 kg/h at 10bar/230°C

  • Max. process pressure

    PN10 ... 160

    Cl.300 ... 2500

  • Medium temperature range

    Compact version:

    -200°C ... 200°C

    -328°F ... 392°F



    Remote version:

    -200°C ... 1000°C

    -328°F ... 1832°F

  • Degree of protection

    Transmitter (Deltabar):

    IP67

    NEMA6P

  • Display/Operation

    Transmitter (Deltabar):

    4-line display

    3 push buttons

    Quick setup

    HistoROM

  • Outputs

    Transmitter (Deltabar):

    4 ... 20 mA

  • Digital communication

    Transmitter (Deltabar):

    HART

    PROFIBUS PA

    FOUNDATION Fieldbus

  • Hazardous area approvals

    Transmitter (Deltabar):

    ATEX

    FM

    CSA

    IEC

    TIIS

    NEPSI

문서 / 매뉴얼 / 소프트웨어

액세서리 / 예비 부품

Nr
Order code
Specification
    • Order code 71071897

      Screw set UNF7/16x1-3/4", steel, Viton

      Consists of: 4x screw, length 1-3/4", steel. 2x seal FKM Viton. Usage: manifold, milled. DA63M, DPD61D/DPD62D/DPD63D, DO61W/DO62C/DO63C/DO65F. Not for manifold + connection IEC61518, both side.

    • Order code 71071899

      Screw set UNF7/16x1-3/4", steel, PTFE

      Consists of: 4x screw, length 1-3/4", steel. 2x seal PTFE. Usage: manifold, milled. DA63M, DPD61D/DPD62D/DPD63D, DO61W/DO62C/DO63C/DO65F. Not for manifold + connection IEC61518, both side.

    • Order code 71071900

      Screw set UNF7/16x2-1/4", steel, Viton

      Consists of: 4x screw, length 2-1/4", steel. 2x seal FKM Viton. Usage: manifold, forging. DA63M, DPD61D/DPD62D/DPD63D, DO61W/DO62C/DO63C/DO65F. Not for manifold + connection IEC61518, both side.

    • Order code 71071901

      Screw set UNF7/16x2-1/4", steel, PTFE

      Consists of: 4x screw, length 2-1/4", steel. 2x seal PTFE. Usage: manifold, forging. DA63M, DPD61D/DPD62D/DPD63D, DO61W/DO62C/DO63C/DO65F. Not for manifold + connection IEC61518, both side.

    • Order code 71285305

      Screw set UNF7/16x1-3/4", VA, Viton

      Consists of: 4x screw, length 1-3/4", VA. 2x seal FKM Viton. Usage: manifold, milled. DA63M, DP61D/DP62D/DP63D, DO61W/DO62C/DO63C/DO65F. Not for manifold + connection IEC61518, both side.

    • Order code 71285307

      Screw set UNF7/16x1-3/4", VA, PTFE

      Consists of: 4x screw, length 1-3/4", VA. 2x seal PTFE. Usage: manifold, milled. DA63M, DP61D/DP62D/DP63D, DO61W/DO62C/DO63C/DO65F. Not for manifold + connection IEC61518, both side.

    • Order code 71285308

      Screw set UNF7/16x2-1/4", VA, Viton

      Consists of: 4x screw, length 2-1/4", VA. 2x seal FKM Viton. Usage: manifold, forging. DA63M, DP61D/DP62D/DP63D, DO61W/DO62C/DO63C/DO65F. Not for manifold + connection IEC61518, both side.

    • Order code 71285310

      Screw set UNF7/16x2-1/4", VA, PTFE

      Consists of: 4x screw, length 2-1/4", VA. 2x seal PTFE. Usage: manifold, forging. DA63M, DP61D/DP62D/DP63D, DO61W/DO62C/DO63C/DO65F. Not for manifold + connection IEC61518, both side.

  • 기존 제품