구성에 따라 다름 |
Coriolis
The single‐tube flowmeter for smallest quantities with extended transmitter functionality. Measuring accurately smallest quantities of liquids and gases for continuous process control.
Highest process safety – self‐drainable measuring tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Nominal diameter: DN 1 to 4 (¹⁄₂₄ to ¹⁄₈"). Process pressure up to 400 bar (5800 psi).
Quality – software for filling & dosing, density & concentration, advanced diagnostics. Flexible data transfer options – numerous communication types. Automatic recovery of data for servicing. 4‐line backlit display with touch control. Device in compact or remote version.
DN 1 to 4 (¹⁄₂₄ to ¹⁄₈")
Measuring tube: 1.4539 (904L); Alloy C22, 2.4602 (UNS N06022)
Connection: 1.4539 (904L); Alloy C22, 2.4602 (UNS N06022); 1.4404 (316/316L)
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.5 %
Density (liquid): ±0.0005 g/cm³
0 to 450 kg/h (0 to 16.5 lb/min)
PN 40, Class 300, 20K, 400 bar (5800 psi)
–50 to +200 °C (–58 to +392 °F)
Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F)
1.4301 (304), corrosion resistant
Powder‐coated die‐cast aluminium
1.4301 (304), sheet
CF3M (316L), cast
IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
4‐line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
4 modular outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive)
Relay
2 modular inputs:
Status
0‐20 mA (active)/4‐20 mA (active/passive)
HART, PROFIBUS PA/DP, FOUNDATION Fieldbus, Modbus RS485,
EtherNet/IP
DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz)
ATEX, IECEx, FM, CSA, NEPSI
3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL
CRN
3-A
CE, C-tick, EAC marking
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
CRN
3.1 material
3-A
Coriolis
The single‐tube flowmeter for smallest quantities with extended transmitter functionality. Measuring accurately smallest quantities of liquids and gases for continuous process control.
Highest process safety – self‐drainable measuring tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Nominal diameter: DN 1 to 4 (¹⁄₂₄ to ¹⁄₈"). Process pressure up to 400 bar (5800 psi).
Quality – software for filling & dosing, density & concentration, advanced diagnostics. Flexible data transfer options – numerous communication types. Automatic recovery of data for servicing. 4‐line backlit display with touch control. Device in compact or remote version.
DN 1 to 4 (¹⁄₂₄ to ¹⁄₈")
Measuring tube: 1.4539 (904L); Alloy C22, 2.4602 (UNS N06022)
Connection: 1.4539 (904L); Alloy C22, 2.4602 (UNS N06022); 1.4404 (316/316L)
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.5 %
Density (liquid): ±0.0005 g/cm³
0 to 450 kg/h (0 to 16.5 lb/min)
PN 40, Class 300, 20K, 400 bar (5800 psi)
–50 to +200 °C (–58 to +392 °F)
Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F)
1.4301 (304), corrosion resistant
Powder‐coated die‐cast aluminium
1.4301 (304), sheet
CF3M (316L), cast
IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
4‐line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
4 modular outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive)
Relay
2 modular inputs:
Status
0‐20 mA (active)/4‐20 mA (active/passive)
HART, PROFIBUS PA/DP, FOUNDATION Fieldbus, Modbus RS485,
EtherNet/IP
DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz)
ATEX, IECEx, FM, CSA, NEPSI
3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL
CRN
3-A
CE, C-tick, EAC marking
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
CRN
3.1 material
3-A
Coriolis
The single-tube system for highest measuring accuracy with minimal flow rates.
-20...+65°C
(-4...+140°F)
-50...+200°C
(-58...+392°F)
PN 16...400
Cl 150...600
JIS 10...63K
904L/1.4539
Alloy C22/2.4602
4...20mA
Pulse/Frequency (10KHz), active/passive
Relays/Status
ATEX
FM
CSA
Coriolis
The single‐tube flowmeter for smallest quantities with extended transmitter functionality. Measuring accurately smallest quantities of liquids and gases for continuous process control.
Highest process safety – self‐drainable measuring tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Nominal diameter: DN 1 to 4 (¹⁄₂₄ to ¹⁄₈"). Process pressure up to 400 bar (5800 psi).
Quality – software for filling & dosing, density & concentration, advanced diagnostics. Flexible data transfer options – numerous communication types. Automatic recovery of data for servicing. 4‐line backlit display with touch control. Device in compact or remote version.
DN 1 to 4 (¹⁄₂₄ to ¹⁄₈")
Measuring tube: 1.4539 (904L); Alloy C22, 2.4602 (UNS N06022)
Connection: 1.4539 (904L); Alloy C22, 2.4602 (UNS N06022); 1.4404 (316/316L)
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.5 %
Density (liquid): ±0.0005 g/cm³
0 to 450 kg/h (0 to 16.5 lb/min)
PN 40, Class 300, 20K, 400 bar (5800 psi)
–50 to +200 °C (–58 to +392 °F)
Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F)
1.4301 (304), corrosion resistant
Powder‐coated die‐cast aluminium
1.4301 (304), sheet
CF3M (316L), cast
IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
4‐line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
4 modular outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive)
Relay
2 modular inputs:
Status
0‐20 mA (active)/4‐20 mA (active/passive)
HART, PROFIBUS PA/DP, FOUNDATION Fieldbus, Modbus RS485, EtherNet/IP
DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz)
ATEX, IECEx, FM, CSA, NEPSI
CE, C-tick, EAC marking
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
CRN
3.1 material
3-A
|
영어 버전 - 12/2014 |
New version available in English
Coriolis flowmeter
Coriolis flowmeter
The Single-tube for smallest quantities with extended transmitter
functionality
pour capteurs Promass F, M, A, I
|
언어: |
French |
|
버전: |
28/05/2004 |
|
파일 크기: |
505 KB |
|
파일 이름: |
BA043Dfr.pdf |
Coriolis Mass Flow Measuring System (with FOUNDATION Fieldbus
interface) for measuring the mass flow rate, density and temperatureof
fluids and gases.The description of the device functions are in a
separate documentation.
Description of the device functions (0ptions and inputs). Additional
documentation for Operating Instructions PROline Promass 83 FOUNDATION
Fieldbus.
| EN | KO | ||
|
01/11/2008
|
|
|
|
|
01/12/2006
|
|
|
|
|
01/12/2005
|
|
|
|
|
01/12/2000
|
|
|
|
언어: |
영어 |
|
버전: |
01/11/2008 |
|
파일 크기: |
1.5 MB |
|
파일 이름: |
BA066DEN_1108.pdf |
Description of the device functions (0ptions and inputs). Additional
documentation for Operating Instructions PROline Promass 83 PR
OFIBUS-DP/-PA.
| EN | KO | ||
|
01/11/2008
|
|
|
|
|
01/01/2006
|
|
|
|
|
01/03/2005
|
|
|
|
|
01/06/2001
|
|
|
|
언어: |
영어 |
|
버전: |
01/11/2008 |
|
파일 크기: |
1.9 MB |
|
파일 이름: |
BA064DEN_1108.pdf |
Descriptions of the device functions (Options and In-/Outputs)
Additional documentation for Operating Instructions Promass 83 MODBUS
RS485.
| EN | KO | ||
|
01/11/2008
|
|
|
|
|
01/12/2005
|
|
|
|
|
01/11/2004
|
|
|
|
언어: |
영어 |
|
버전: |
01/11/2008 |
|
파일 크기: |
1.8 MB |
|
파일 이름: |
BA108DEN_1108.pdf |
Coriolis flowmeter
Coriolis flowmeter
Coriolis Mass Flow Measuring System (with PROFIBUS DP/PA interface)
for measuring the mass flow rate, density and temperature of fluids and
gases. The description of the device functions are in a separate
documentation.
Coriolis Mass Flow Measuring System (with Modbus RS485
interface) for measuring the mass flow rate, density and temperature of
fluids and gases.The description of the device functions are in a
separate documentation.
| EN | KO | ||
|
15/10/2012
|
|
|
|
|
01/10/2011
|
|
|
|
|
08/06/2010
|
|
|
|
|
01/11/2008
|
|
|
|
언어: |
영어 |
|
버전: |
15/10/2012 |
|
파일 크기: |
2.5 MB |
|
파일 이름: |
BA00107DEN_1412.pdf |
당사는 쿠키를 사용해 사용자의 브라우징 경험을 개선하고, 통계를 수집하여 사이트 기능을 최적화하고, 맞춤형 광고 또는 콘텐츠를 제공합니다.
"모두 허용"을 선택하면 쿠키 사용에 동의하는 것으로 간주됩니다.
자세한 내용은 쿠키 정책 을 참조하시기 바랍니다.