키워드, 주문 또는 제품 코드 또는 일련 번호를 검색해 보십시오(예: “CM442” 또는 “기술 정보”).
검색하려면 최소 2자 이상 입력하십시오.
Bioprocessing Raman spectroscopy calibration and verification kit for the Raman flow assembly

Raman calibration and verification kits

Everything needed to calibrate and verify your Raman analyzer system for lab-to-process scalability

KRCAL
Please Wait (spinning wheel)
가격 로드 중
일시적으로 가격을 로드할 수 없습니다.
Price on request
가격 활성화 중
가격: 정보 제공
측정/작업 필터링
측정값

이 제품의 CAD 도면을 다운로드하도록 설정

  • 측정 원리

    Raman spectroscopy

  • Temperature

    Operating:
    0 to 40 °C /32 to 104 °F
    Storage:
    -15 to 50 °C / 5 to 122 °F

  • Relative humidity

    Storage:
    < 80 % Non-Condensing

  • Unit dimensions (width x height x depth)

    Kit: 235 x 192 x 85 mm
    9.3 x 7.6 x 3.4 inch

  • Weight

    Kit: 1.5 kg / 3.3 lbs

  • Sampling probe compatibility

    Raman Rxn-10 (with bio multi optic)

  • Spectral intensity reference

    Calibration Reference Standard

  • Spectral intensity output repeatability (at time of certification)

    < ±2 %

  • Long term spectral uncertainty (at any wavelength)

    ±6.05 %

  • Spectral intensity calibration range

    CRS-785: 790.7 to 1074.5 nm

  • 측정 원리

    Raman spectroscopy

  • Temperature

    Operating:
    0 to 40 °C /32 to 104 °F
    Storage:
    -15 to 50 °C / 5 to 122 °F

  • Relative humidity

    Storage:
    < 80 % Non-Condensing

  • Unit dimensions (width x height x depth)

    Kit: 235 x 192 x 85 mm
    9.3 x 7.6 x 3.4 inch

  • Weight

    Kit: 1.5 kg / 3.3 lbs

  • Sampling probe compatibility

    Raman Rxn-10 (with Raman flow bench)

  • Spectral intensity reference

    Calibration Reference Standard

  • Spectral intensity output repeatability (at time of certification)

    < ±2 %

  • Long term spectral uncertainty (at any wavelength)

    ±6.05 %

  • Spectral intensity calibration range

    CRS-785: 790.7 to 1074.5 nm

  • 측정 원리

    Raman spectroscopy

  • Temperature

    Operating:
    0 to 40 °C /32 to 104 °F
    Storage:
    -15 to 50 °C / 5 to 122 °F

  • Relative humidity

    Storage:
    < 80 % Non-Condensing

  • Unit dimensions (width x height x depth)

    Kit: 235 x 192 x 85 mm
    9.3 x 7.6 x 3.4 inch

  • Weight

    Kit: 1.5 kg / 3.3 lbs

  • Sampling probe compatibility

    Raman Rxn-46

  • Spectral intensity reference

    Calibration Reference Standard

  • Spectral intensity output repeatability (at time of certification)

    < ±2 %

  • Long term spectral uncertainty (at any wavelength)

    ±6.05 %

  • Spectral intensity calibration range

    CRS-785: 790.7 to 1074.5 nm