키워드, 주문 또는 제품 코드 또는 일련 번호를 검색해 보십시오(예: “CM442” 또는 “기술 정보”).
검색하려면 최소 2자 이상 입력하십시오.
Hygienic mass flowmeter with highest repeatability and compact transmitter for filling and dosing

Dosimass Coriolis flowmeter

Mass flowmeter with hygienic design, highest repeatability and a compact transmitter

D8AB
Please Wait (spinning wheel)
가격 로드 중
일시적으로 가격을 로드할 수 없습니다.
Price on request
가격 활성화 중
가격: 정보 제공
측정/작업 필터링
측정값

이 제품의 CAD 도면을 다운로드하도록 설정

  • 측정 원리

    Coriolis

  • Product headline

    The compact sensor with an ultra-compact transmitter.
    Measurement of liquids with the most diverse properties in continuous process control & batching applications.

  • Sensor features

    High process safety – high measuring accuracy for different media in shortest filling time. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
    Nominal diameter: DN 1 to 40 (¹⁄₂₄ to 1¹⁄₂"). Various hygienic process connections, 3-A conform. CIP, SIP cleanable sensor.

  • Transmitter features

    Versatile and time-saving wiring – plug connector. Fast commissioning – pre-configured devices. Automatic recovery of data for servicing.
    Robust, ultra‐compact transmitter housing. Pulse/frequency/switch output, Modbus RS485. Excellent and easily cleanable transmitter.

  • Nominal diameter range

    DN 1 to 40 (¹⁄₂₄ to 1¹⁄₂")

  • Wetted materials

    Measuring tube:
    1.4435 (316/316L) (DN 1 to 4 mm (¹⁄₂₄ to ¹⁄₈")
    1.4539 (904L) (DN 8 to 40 mm (³⁄₈ to 1 ½")
    Process connection
    1.4435 (316/316L) (DN 1 to 4 mm (¹⁄₂₄ to ¹⁄₈")
    1.4539 (904L) (DN 8 to 40 mm (³⁄₈ to 1 ½")

  • Measured variables

    Mass flow, density, temperature, volume flow

  • Max. measurement error

    Mass flow (liquid): ±0.15 %
    Density (liquid): ±0.0005 g/cm³

  • Measuring range

    0 to 45 000 kg/h (0 to 1654 lb/min)

  • Max. process pressure

    PN 40

  • Medium temperature range

    –40 to +130 °C (–40 to +266 °F)
    150 °C allowed for 1 h

  • Ambient temperature range

    –20 to +60 °C (–4 to +140 °F)

  • Sensor housing material

    Stainless steel, 1.4404 (316/316L) (DN 1 to 4 mm (¹⁄₂₄ to ¹⁄₈")
    Stainless steel, 1.4301 (304) (DN 8 to 40 mm (³⁄₈ to 1 ½")

  • Transmitter housing material

    Stainless steel, 1.4409 (CF3M)

  • Degree of protection

    IP67, type 4X enclosure

  • Display/Operation

    No local operation
    Configuration via operating tools possible

  • Outputs

    Pulse/frequency/switch output (passive)

  • Inputs

    None

  • Digital communication

    Modbus RS485, IO-Link

  • Power supply

    DC 20 to 30 V

  • Hazardous area approvals

    ATEX, UL, UK Ex

  • Other approvals and certificates

    3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
    3-A

  • Product safety

    CE