  • 측정 원리

    TDLAS

  • Product Headline

    Single channel gas analyzer for moisture (H2O) in the natural gas industry. The sensor measures gas using tunable diode laser absorption spectroscopy (TDLAS) to determine the concentration of the gas without coming into physical contact with the stream.

  • Channels

    1

  • Analyte and Measurement ranges

    H2O (Moisture):
    0 to 100 ppmv (minimum)
    0 to 5000 ppmv (maximum)

  • Measured Variables

    Concentration
    Moisture Dew Point
    Cell Pressure
    Cell Temperature

  • Ambient Temperature range

    -20 to 50°C (-4 to 122°F)

  • Operating Pressure range

    Inlet Pressure: 140 to 350 kPa (20 to 50 psig)
    Sample Cell: 700 to 1400 mbara

  • Analyzer Wetted materials

    316L stainless steel
    FKM O-Rings
    Glass

  • Power supply

    100 to 240 VAC, 50 to 60 Hz
    or
    9 to 16 VDC or 18 to 32 VDC - optional
    1 Amp maximum at 120 VAC
    1.6 Amp at 24VDC, 3.2 Amp at 12 VDC

  • Communication

    Analog Output: 1 or 2 4-20mA Isolated, 1200 ohms at 24 VDC max load
    Serial: RS232C
    Protocol: Modbus Gould RTU or Daniel RTU or ASCII
    Alarms: 2, General Fault and Concentration Alarms via Modbus and Analog Output(s)

  • Housing materials

    Electronics: 304 stainless steel (Class I Division 2)
    Electronics: Cast Aluminum (Class I Division 1)
    Sample System Panel: Anodized aluminum

  • Hazardous area approvals

    CSA Class I, Division 1
    CSA Class I, Division 2
    CSA Class I, Zone 2

  • Degree of protection

    Type 3R (Class I Division 2)
    Type 4 (Class I Division 1)

  • 측정 원리

    TDLAS

  • Product Headline

    Single channel gas analyzer for carbon dioxide (CO2) in the natural gas industry. The sensor measures gas using tunable diode laser absorption spectroscopy (TDLAS) to determine the concentration of the gas without coming into physical contact with the stream.

  • Channels

    1

  • Analyte and Measurement ranges

    CO2 (Carbon Dioxide):
    0 to 5% volume (minimum)
    0 to 50% volume (maximum)

  • Measured Variables

    Concentration
    Cell Pressure
    Cell Temperature

  • Ambient Temperature range

    -20 to 50°C (-4 to 122°F)

  • Operating Pressure range

    Inlet Pressure: 140 to 350 kPa (20 to 50 psig)
    Sample Cell: 700 to 1400 mbara

  • Analyzer Wetted materials

    316L stainless steel
    FKM O-Rings
    Glass

  • Power supply

    100 to 240 VAC, 50 to 60 Hz
    or
    9 to 16 VDC or 18 to 32 VDC - optional
    1 Amp maximum at 120 VAC
    1.6 Amps at 24 VDC, 3.2 Amps at 12 VDC

  • Communication

    Analog Output: 1 or 2 4-20mA Isolated, 1200 ohms at 24 VDC max load
    Serial: RS232C
    Protocol: Modbus Gould RTU or Daniel RTU or ASCII
    Alarms: 2, General Fault and Concentration Alarms via Modbus and Analog Output(s)

  • Housing materials

    Electronics: 304 stainless steel (Class I Division 2)
    Electronics: Cast Aluminum (Class I Division 1)
    Sample System Panel: Anodized aluminum

  • Hazardous area approvals

    CSA Class I, Division 1
    CSA Class I, Division 2
    CSA Class I, Zone 2

  • Degree of protection

    Type 3R (Class I Division 2)
    Type 4 (Class I Division 1)