키워드, 주문 또는 제품 코드 또는 일련 번호를 검색해 보십시오(예: “CM442” 또는 “기술 정보”).
검색하려면 최소 2자 이상 입력하십시오.
Gammapilot FTG20 - Radiometric point level

Radiometric
Point level detection
Gammapilot FTG20

Geiger-Mueller counter for point level detection with separate transmitter

FTG20
Please Wait (spinning wheel)
가격 로드 중
일시적으로 가격을 로드할 수 없습니다.
Price on request
가격 활성화 중
가격: 정보 제공
측정/작업 필터링
측정값

이 제품의 CAD 도면을 다운로드하도록 설정

  • 측정 원리

    Radiometric Limit

  • Characteristic / Application

    Radiometric Transmitter with 1 to 3 Geiger-Müller counters for contactless measurement in liquids, sludge or suspensions under exteme process conditions

  • Specialities

    Calculation and sizing with Applicator

  • Supply / Communication

    Relay DPDT:
    19...253VAC, 19...55VDC
    8/16mA:
    11...36VDC, 11..30VDC (Exia)

  • Ambient temperature

    Relay DPDT:
    19...253VAC, 19...55VDC
    8/16mA:
    11...36VDC, 11..30VDC (Exia)

  • Process temperature

    Any

  • Process pressure / max. overpressure limit

    Any

  • Min. density of medium

    Any

  • Min. conductivity of medium

    Any

  • Main wetted parts

    Non-contact

  • Process connection

    Non-contact

  • Process connection hygienic

    Non-contact

  • Sensor length

    140 mm (5.5")

  • Communication

    Relay DPDT
    8/16mA
    4...20mA

  • Certificates / Approvals

    ATEX, CSA, CSA C/US, IEC Ex, NEPSI, EAC

  • Options

    Sensitivity:
    1x Geiger- counter: 1-8uSv/h,
    2x Geiger- counter: 0,5-4uSv/h
    3x Geiger- counter: 0,3-2,7uSv/h
    Cooling jacket
    Transmitter with compartment for conduit

  • Components

    Isotope: FSG60, FSG61
    Source container: FQG60, FQG61, FQG62, FQG63, QG2000

  • 측정 원리

    Radiometric Limit

  • Characteristic / Application

    Radiometric Transmitter with 1 to 3 Geiger-Müller counters for contactless measurement in solids under exteme process conditions

  • Specialities

    Calculation and sizing with Applicator

  • Supply / Communication

    Relay DPDT:
    19...253VAC, 19...55VDC
    8/16mA:
    11...36VDC, 11..30VDC (Exia)

  • Ambient temperature

    -40...70°C,
    (-40...158°F),
    With cooling jacket:
    0...120°C
    (32...248°F)

  • Process temperature

    Any

  • Process pressure / max. overpressure limit

    Any

  • Min. density of medium

    Any

  • Main wetted parts

    Non-contact

  • Process connection

    Non-contact

  • Process connection hygienic

    Non-contact

  • Sensor length

    140 mm (5.5")

  • Communication

    Relay DPDT
    8/16mA
    4...20mA

  • Certificates / Approvals

    ATEX, CSA C/US, IEC Ex, NEPSI, EAC

  • Options

    Sensitivity:
    1x Geiger- counter: 1-8uSv/h,
    2x Geiger- counter: 0,5-4uSv/h
    3x Geiger- counter: 0,3-2,7uSv/h
    Cooling jacket
    Transmitter with compartment for conduit

  • Components

    Isotope: FSG60, FSG61
    Source container: FQG60, FQG61, FQG62, FQG63, QG2000