키워드, 주문 또는 제품 코드 또는 일련 번호를 검색해 보십시오(예: “CM442” 또는 “기술 정보”).
검색하려면 최소 2자 이상 입력하십시오.
멀티채널, 멀티파라미터 소프트웨어
Memobase Plus CYZ71D

멀티채널, 멀티파라미터 소프트웨어
Memobase Plus CYZ71D

Memosens 센서를 위한 단일 도구를 사용한 측정, 교정 및 문서화

CYZ71D
Please Wait (spinning wheel)
가격 로드 중
일시적으로 가격을 로드할 수 없습니다.
Price on request
가격 활성화 중
가격: 정보 제공
from CHF ??.-
측정/작업 필터링
측정값

이 제품의 CAD 도면을 다운로드하도록 설정

  • 측정 원리

    Potentiometric

  • Application

    Measurement, calibration and documentation of Memosens sensors in laboratories, up to four channels

  • Installation

    Laboratory or work bench applications in safe area, no connection to PCS!

  • Characteristic

    Product consists of PC software, USB cable, sensor connection box MemoLink and Memosens lab cable CYK20 optionally, CYK10 with M12 plug can be used alternatively

  • Measurement range

    Dependent on connected sensors, please see sensor specifications

  • Measuring principle

    Memosens and measuring principles of the connected sensors

  • Material

    MemoLink sensor connection box: PBT

  • Dimension

    MemoLink sensor connection box:
    97.0 x 31.5 x 77.5 mm
    3.82 x 1.24 x 3.05 inch

  • Ex certification

    ATEX II (2)G (Ex ia Gb) IIc which enables to connect Ex- and non-ex sensors alternating to the MemoLoink box without loosing the sensor's approval
    PC, USB cable and MemoLink in safe area only!

  • Ingress protection

    MemoLink: IP 65 when cables are connected

  • Input

    Memosens

  • Output / communication

    USB

  • Additional certifications

    FDA CFR 21 Part 11 Certificate of compliance when Pharma conformity is ordered

  • 측정 원리

    Conductive

  • Application

    Measurement, calibration and documentation of Memosens sensors in laboratories, up to four channels

  • Installation

    Laboratory or work bench applications in safe area
    No connection to PCS!

  • Characteristic

    Product consists of PC software, USB cable, sensor connection box MemoLink and Memosens lab cable CYK20 optionally, CYK10 with M12 plug can be used alternatively

  • Measurement range

    Dependent on connected sensors, please see sensor specifications

  • Measuring principle

    Memosens + measuring principles of the connected sensors

  • Material

    MemoLink sensor connection box: PBT

  • Dimension

    MemoLink sensor connection box:
    97.0 x 31.5 x 77.5 mm
    3.82 x 1.24 x 3.05 inch

  • Ex certification

    ATEX II (2)G (Ex ia Gb) IIc which enables to connect Ex- and non-ex sensors alternating to the MemoLoink box without loosing the sensor's approval
    PC, USB cable and MemoLink in safe area only!

  • Ingress protection

    MemoLink: IP 65 when cables are connected

  • Input

    Memosens

  • Output / communication

    USB

  • Additional certifications

    FDA CFR 21 Part 11 Certificate of compliance when Pharma conformity is ordered

  • 측정 원리

    Amperometric oxygen measurement

  • Application

    Measurement, calibration and documentation of Memosens sensors in laboratories, up to four channels

  • Installation

    Laboratory or work bench applications in safe area
    No connection to PCS!

  • Characteristic

    Product consists of PC software, USB cable, sensor connection box MemoLink and Memosens lab cable CYK20 optionally, CYK10 with M12 plug can be used alternatively

  • Measurement range

    Dependent on connected sensors, please see sensor specifications

  • Measuring principle

    Memosens and measuring principles of the connected sensors

  • Material

    MemoLink sensor connection box: PBT

  • Dimension

    MemoLink sensor connection box:
    97.0 x 31.5 x 77.5 mm
    3.82 x 1.24 x 3.05 inch

  • Ex certification

    ATEX II (2)G (Ex ia Gb) IIc which enables to connect Ex- and non-ex sensors alternating to the MemoLoink box without loosing the sensor's approval.
    PC, USB cable and MemoLink in safe area only!

  • Ingress protection

    MemoLink: IP 65 when cables are connected.

  • Input

    Memosens

  • Output / communication

    USB

  • Additional certifications

    FDA CFR 21 Part 11 Certificate of compliance when Pharma conformity is ordered