FMU9x에 연결 가능한 레벨 및 유량 측정용 초음파 센서(측정 범위 최대 25m)

FDU93
Please Wait (spinning wheel)
가격 로드 중
일시적으로 가격을 로드할 수 없습니다.
Price on request
가격 활성화 중
가격: 정보 제공
from CHF ??.-
측정/작업 필터링
측정값

이 제품의 CAD 도면을 다운로드하도록 설정

  • 측정 원리

    Ultrasonic

  • Characteristic / Application

    Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300 m in-between sensor and transmitter

  • Supply / Communication

    4-wire (HART, Profibus DP)

  • Accuracy

    +/- 2 mm + 0.17% of measured distance

  • Ambient temperature

    -40 °C ... 95 °C
    (-40 °F ... 203 °F)

  • Process temperature

    -40 °C ... 95 °C
    (-40 °F ... 203 °F)

  • Process pressure / max. overpressure limit

    0.7 bar ... 3 bar abs
    (10 psi ... 43 psi)

  • Main wetted parts

    UP (unsaturated polyester)
    Silicon / Al PTFE coated

  • Process connection

    G / NPT 1"

  • Blocking distance

    0.6 m (2 ft)

  • Max. measurement distance

    Liquids: 25 m (85 ft),
    Solids: 15 m (50 ft)

  • Communication

    Transmitter:
    4...20 mA HART
    Profibus DP

  • Certificates / Approvals

    ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, EAC Ex

  • Options

    Second 4...20 mA output

  • Components

    Transmitter:
    FMU90, FMU95

  • Application limits

    For tank farms scanner:
    FMU95

  • 측정 원리

    Ultrasonic

  • Characteristic / Application

    Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300m in-between sensor and transmitter

  • Supply / Communication

    4-wire (HART , Profibus DP)

  • Accuracy

    +/- 2mm + 0.17% of measured distance

  • Ambient temperature

    -40 °C ... 95 °C
    (-40 °F ... 203 °F)

  • Process temperature

    -40 °C ... 95 °C
    (-40 °F ... 203 °F)

  • Process pressure / max. overpressure limit

    0.7 bar ... 3 bar abs
    (10 psi ... 43 psi)

  • Main wetted parts

    UP (unsaturated polyester)
    Silicon / Al PTFE coated

  • Process connection

    G / NPT 1"

  • Blocking distance

    0.6 m (2 ft)

  • Max. measurement distance

    Liquids: 25 m (85 ft),
    Solids: 15 m (50 ft)

  • Communication

    Transmitter:
    4 ... 20 mA HART
    Profibus DP

  • Certificates / Approvals

    ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, EAC Ex

  • Options

    Second 4...20mA output

  • Components

    Transmitter:
    FMU90