측정/작업 필터링
측정값

이 제품의 CAD 도면을 다운로드하도록 설정

  • 측정 원리

    Absolute and gauge pressure

  • Characteristic

    Pressure transmitter with
    metal membrane for accurate
    measurement in liquids or gases.
    Available with diaphragm seals.
    Intuitive and clear wizard for
    commissioning.

  • Supply voltage

    Ex d, Ex e, non-Ex:
    10.5...35V DC
    Ex i: 10.5...30V DC

  • Reference Accuracy

    Standard:
    up to 0.065 %
    Platinum:
    up to 0.055 %

  • Long term stability

    0.1 % of URL/ year
    0.2 % of URL/ 5 years
    0.25 % of URL/ 10 years

  • Process temperature

    Standard:
    -40°C…+125°C
    (-40°F...+257°F)
    Diaphragm seal:
    -70°C...+400°C
    (-94°F...+752°F)

  • Ambient temperature

    -40°C...+85°C
    (-40°F...+185°F)

  • Measuring cell

    1 bar...400 bar
    (14.5 psi...5800 psi)

  • Smallest calibratable span

    20 mbar (0.29 psi)

  • Vacuum resistance

    Standard:10 mbar (0.145 psi)
    Diaphragm seal: 50 mbar (0.725 psi)

  • Max. Turn down

    20:1

  • Max. overpressure limit

    600 bar (9,000 psi)

  • Process connection

    Thread:
    G1/2, NPT1/2
    Flange:
    DN25...DN80,
    NPS 1"...3"

  • Material process membrane

    316L, AlloyC, Gold

  • Material gasket

    PTFE

  • Fill fluid

    Silicone oil, high temperature oil,
    Inert oil

  • Material housing

    Aluminum, 316L

  • Communication

    4...20 mA HART

  • Certificates / Approvals

    ATEX, FM, IECEx, JPN Ex,
    INMETRO, NEPSI

  • Safety approvals

    SIL

  • Design approvals

    EN10204-3.1,
    NACE MR0103,
    NACE MR0175

  • Specialities

    Zero/Span buttons,
    Testclamp,
    RFID TAG for easy identification

  • 측정 원리

    Absolute and gauge pressure

  • Characteristic / Application

    Pressure transmitter with
    metal membrane for accurate
    measurement in liquids or gases.
    Available with diaphragm seals.
    Intuitive and clear wizard for
    commissioning.

  • Specialities

    zero/span button
    test clamp
    RFID TAG for easy identification

  • Supply / Communication

    Ex d, Ex e, non-Ex:
    10.5...35V DC
    Ex i: 10.5...30V DC

  • Accuracy

    Standard:
    up to 0.065 %
    Platinum:
    up to 0.055 %

  • Long term stability

    0.1 % of URL/ year
    0.2 % of URL/ 5 years
    0.25 % of URL/ 10 years

  • Ambient temperature

    -40°C...+85°C
    (-40°F...+185°F)

  • Process temperature

    Standard:
    -40°C…+125°C
    (-40°F...+257°F)
    Diaphragm seal:
    -70°C...+400°C
    (-94°F...+752°F)

  • Process connection

    Thread:
    G1/2, NPT1/2
    Flange:
    DN25...DN80,
    NPS 1"...3"

  • Communication

    4...20 mA HART

  • Certificates / Approvals

    ATEX, FM, IECEx, JPN Ex,
    INMETRO, NEPSI

  • Safety approvals

    SIL

  • Design approvals

    EN10204-3.1,
    NACE MR0103,
    NACE MR0175