Combines in-line viscosity and flow measurement with extended transmitter functionality

The straight single-tube design of the Promass 83I, provides the regular Coriolis flowmeter outputs of mass flow, density and temperature, additionally it provides in-line viscosity measurement as an optional output. It offers premium accuracy in measurement of liquids and gases. It will be the preferred solution for customers using extended functionality like software options for filling and dosing, concentration measurement or advanced diagnostics.

  • 장점

    • Energy-saving – full bore design enables minimal pressure loss

    • Fewer process measuring points – multivariable measurement (flow, density, temperature)

    • Space-saving installation – no in/outlet run needs

    • Quality – software for filling & dosing, density &...

  • 적용 분야

    • Measuring principle operates independently of physical fluid properties such as viscosity or density

    • Measuring liquids and gases in applications requiring low pressure loss and gentle fluid treatment.

    Device properties

    • Straight, easy cleanable single-...

Details

  • 측정 원리

    Coriolis

  • Product headline

    Combines in‐line viscosity and flow measurement with extended transmitter functionality. Measuring liquids and gases in applications requiring low pressure loss and gentle fluid treatment.

  • Sensor features

    Energy‐saving – full bore design enables minimal pressure loss. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Straight, easy cleanable single‐tube system. TMB technology.

  • Transmitter features

    Quality – software for filling & dosing, density & concentration, advanced diagnostics. Flexible data transfer options – numerous communication types. Automatic recovery of data for servicing. 4‐ line backlit display with touch control. Device in compact or remote version.

  • Nominal diameter range

    DN 8 to 80 (⅜ to 3")

  • Wetted materials

    Measuring tube: Titanium grade 9
    Connection: Titanium grade 2

  • Measured variables

    Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration, viscosity

  • Max. measurement error

    Mass flow (liquid): ±0.1 %
    Volume flow (liquid): ±0.1 %
    Mass flow (gas): ±0.5 %
    Density (liquid): ±0.0005 g/cm³

  • Measuring range

    0 to 180 000 kg/h (0 to 6600 lb/min)

  • Max. process pressure

    PN 100, Class 600, 63K

  • Medium temperature range

    –50 to +150 °C (–58 to +302 °F)

  • Ambient temperature range

    Standard: –20 to +60 °C (–4 to +140 °F)
    Option: –40 to +60 °C (–40 to +140 °F)

  • Sensor housing material

    1.4301/1.4307 (304L), corrosion resistant

  • Transmitter housing material

    Powder‐coated die‐cast aluminium
    1.4301 (304), sheet
    CF3M (316L), cast

  • Degree of protection

    IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure

  • Display/Operation

    4‐line backlit display with touch control (operation from outside)
    Configuration via local display and operating tools possible

  • Outputs

    4 modular outputs:
    0‐20 mA (active)/4‐20 mA (active/passive)
    Pulse/frequency/switch output (passive)
    Relay

  • Inputs

    2 modular inputs:
    Status
    0‐20 mA (active)/4‐20 mA (active/passive)

  • Digital communication

    HART, PROFIBUS PA/DP, FOUNDATION Fieldbus, Modbus RS485, EtherNet/IP

  • Power supply

    DC 16 to 62 V
    AC 85 to 260 V (45 to 65 Hz)
    AC 20 to 55 V (45 to 65 Hz)

  • Hazardous area approvals

    ATEX, IECEx, FM, CSA, NEPSI, TIIS

  • Other approvals and certificates

    3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL
    PED, CRN
    3-A

  • Product safety

    CE, C-tick, EAC marking

  • Functional safety

    Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

  • Metrological approvals and certificates

    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR

  • Pressure approvals and certificates

    PED, CRN

  • Material certificates

    3.1 material

  • Hygienic approvals and certificates

    3-A, EHEDG

  • 측정 원리

    Coriolis

  • Main features

    Balanced singe-tube system, "Fit-and-Forget" installation, viscosity measurement


    Design:
    Easy to clean, hygienic, careful handling of the medium

  • Diameter

    DN 8...80
    5/16"...3"

  • Measuring range

    0...180'000 kg/h
    0... 20'000 cP (viscosity)

  • Process temperature

    -50...+150°C
    (-58...+302°F)

  • Pressure range

    PN 16...100
    CI 150...600
    JIS 10...63K

  • Measurement error

    Mass flow: +-0.1%
    Volume flow: +-0.5%
    Viscosity: ± 5% ± 0.5 mPa•s (Newtonian fluids)
    Density: +- 0.004g/cc

  • Display/Operation

    Four line backlit
    Touch control

  • Inputs

    Status
    Current input

  • Outputs

    0/4...20mA
    Pulse Frequency (10KHz), active/passive
    Relays/Status

  • Communication

    HART
    PROFIBUS PA
    Profibus DP
    FOUNDATION Fieldbus

  • Ex-Approvals

    ATEX
    FM
    CSA

  • Protection electronic

    IP 67
    NEMA 4x

  • Features

    S-DAT, T-DAT, F-Chip
    Validation
    Quick Set-up
    3 Totalizers
    Pulsating Flow
    Advanced diagnostics
    Batching
    Concentration measurement

  • Advantages

    Balanced single-tube system.

    Dual mode for independent viscosity measurement.

    High vibration immunity.

    Easy and cost-effective mounting.

    Measurement is independent of fluid properties.

    Promass 83 with "Touch Control": Operation from outside without opening the house.

    Software pagackes may be updated for:

    - Dosage applications

    - Concentration measurement

    - Advanced diagnostics

    "Quick Setup" menus for straightforward commissioning in the field.

  • 측정 원리

    Coriolis

  • Product headline

    Combines in‐line viscosity and flow measurement with extended transmitter functionality. Measuring liquids and gases in applications requiring low pressure loss and gentle fluid treatment.

  • Sensor features

    Energy‐saving – full bore design enables minimal pressure loss. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Straight, easy cleanable single‐tube system. TMB technology.

  • Transmitter features

    Quality – software for filling & dosing, density & concentration, advanced diagnostics. Flexible data transfer options – numerous communication types. Automatic recovery of data for servicing. 4‐ line backlit display with touch control. Device in compact or remote version.

  • Nominal diameter range

    DN 8 to 80 (⅜ to 3")

  • Wetted materials

    Measuring tube: Titanium grade 9
    Connection: Titanium grade 2

  • Measured variables

    Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration, viscosity

  • Max. measurement error

    Mass flow (liquid): ±0.1 %
    Volume flow (liquid): ±0.1 %
    Mass flow (gas): ±0.5 %
    Density (liquid): ±0.0005 g/cm³

  • Measuring range

    0 to 180 000 kg/h (0 to 6600 lb/min)

  • Max. process pressure

    PN 100, Class 600, 63K

  • Medium temperature range

    –50 to +150 °C (–58 to +302 °F)

  • Ambient temperature range

    Standard: –20 to +60 °C (–4 to +140 °F)
    Option: –40 to +60 °C (–40 to +140 °F)

  • Sensor housing material

    1.4301/1.4307 (304L), corrosion resistant

  • Transmitter housing material

    Powder‐coated die‐cast aluminium
    1.4301 (304), sheet
    CF3M (316L), cast

  • Degree of protection

    IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure

  • Display/Operation

    4‐line backlit display with touch control (operation from outside)
    Configuration via local display and operating tools possible

  • Outputs

    4 modular outputs:
    0‐20 mA (active)/4‐20 mA (active/passive)
    Pulse/frequency/switch output (passive)
    Relay

  • Inputs

    2 modular inputs:
    Status
    0‐20 mA (active)/4‐20 mA (active/passive)

  • Digital communication

    HART, PROFIBUS PA/DP, FOUNDATION Fieldbus, Modbus RS485, EtherNet/IP

  • Power supply

    DC 16 to 62 V
    AC 85 to 260 V (45 to 65 Hz)
    AC 20 to 55 V (45 to 65 Hz)

  • Hazardous area approvals

    ATEX, IECEx, FM, CSA, NEPSI, TIIS

  • Other approvals and certificates

    3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL
    PED, CRN
    3-A

  • Product safety

    CE, C-tick, EAC marking

  • Functional safety

    Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

  • Metrological approvals and certificates

    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR

  • Pressure approvals and certificates

    PED, CRN

  • Material certificates

    3.1 material

  • Hygienic approvals and certificates

    3-A, EHEDG

  • 측정 원리

    Coriolis

  • Product headline

    Combines in‐line viscosity and flow measurement with extended transmitter functionality. Measuring liquids and gases in applications requiring low pressure loss and gentle fluid treatment.

  • Sensor features

    Energy‐saving – full bore design enables minimal pressure loss. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Straight, easy cleanable single‐tube system. TMB technology.

  • Transmitter features

    Quality – software for filling & dosing, density & concentration, advanced diagnostics. Flexible data transfer options – numerous communication types. Automatic recovery of data for servicing. 4‐ line backlit display with touch control. Device in compact or remote version.

  • Nominal diameter range

    DN 8 to 80 (⅜ to 3")

  • Wetted materials

    Measuring tube: Titanium grade 9
    Connection: Titanium grade 2

  • Measured variables

    Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration, viscosity

  • Max. measurement error

    Mass flow (liquid): ±0.1 %
    Volume flow (liquid): ±0.1 %
    Mass flow (gas): ±0.5 %
    Density (liquid): ±0.0005 g/cm³

  • Measuring range

    0 to 180 000 kg/h (0 to 6600 lb/min)

  • Max. process pressure

    PN 100, Class 600, 63K

  • Medium temperature range

    –50 to +150 °C (–58 to +302 °F)

  • Ambient temperature range

    Standard: –20 to +60 °C (–4 to +140 °F)
    Option: –40 to +60 °C (–40 to +140 °F)

  • Sensor housing material

    1.4301/1.4307 (304L), corrosion resistant

  • Transmitter housing material

    Powder‐coated die‐cast aluminium
    1.4301 (304), sheet
    CF3M (316L), cast

  • Degree of protection

    IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure

  • Display/Operation

    4‐line backlit display with touch control (operation from outside)
    Configuration via local display and operating tools possible

  • Outputs

    4 modular outputs:
    0‐20 mA (active)/4‐20 mA (active/passive)
    Pulse/frequency/switch output (passive)
    Relay

  • Inputs

    2 modular inputs:
    Status
    0‐20 mA (active)/4‐20 mA (active/passive)

  • Digital communication

    HART, PROFIBUS PA/DP, FOUNDATION Fieldbus, Modbus RS485, EtherNet/IP

  • Power supply

    DC 16 to 62 V
    AC 85 to 260 V (45 to 65 Hz)
    AC 20 to 55 V (45 to 65 Hz)

  • Hazardous area approvals

    ATEX, IECEx, FM, CSA, NEPSI, TIIS

  • Product safety

    CE, C-tick, EAC marking

  • Functional safety

    Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

  • Metrological approvals and certificates

    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR

  • Pressure approvals and certificates

    PED, CRN

  • Material certificates

    3.1 material

  • Hygienic approvals and certificates

    3-A, EHEDG

  • 측정 원리

    Coriolis

  • Characteristic / Application

    Balanced single-tube system, "Fit-and-Forget" installation
    Design:
    Easy to clean, hygienic, careful handling of the medium
    - chemically resistant material

  • Ambient temperature

    -20...+65°C
    (-4...+140°F)

  • Process temperature

    -50...+150°C
    (-58...+302°F)

  • Process pressure absolute

    PN 16...100
    Cl 150...600
    JIS 10...63K

  • Wetted parts

    Titan

  • Output

    4...20mA
    Pulse/Frequency (10KHz), active/passiveRelays/Status

  • Certificates / Approvals

    ATEX
    FM
    CSA

문서 / 매뉴얼 / 소프트웨어